RenewAire® Energy Recovery Ventilators
- Product Overview
- Styles & Options
With a wide range of models and airflows, RenewAire® features all of the excellent sound attenuation and energy recovery benefits of RenewAire’s HIGH-EFFICIENCY, STATIC-PLATE ENTHALPY-CORE, with the flexibility of a multitude of configurations and installations. With the option of outdoor or indoor models, horizontal or vertical orientations, and a variety of supply, return, exhaust, and outside air combinations, RenewAire® can adapt to suit any project.
With a wide airflow range of 40 CFM to 11,000 CFM, RenewAire® can suit many applications from single home residential projects to larger commercial building applications. Built for maximum efficiency, this exceptional ERV features an EC motor or variable frequency drive, on select models, for superior speed control compared to a standard PSC motor. With RenewAire®, your project will benefit from cleaner, healthier air, with the convenience of an integrated DDC controller for BMS® and BACnet® communication.
- LE6XINH INDOOR – 1,500-6,600 CFM
- LE6XINV INDOOR – 1,500-6,600 CFM
- LE6XRT ROOFTOP – 1,500-6,600 CFM
- LE8XINH INDOOR – 2,000-8,800 CFM
- LE8XINV INDOOR – 2,000-8,800 CFM
- LE8XRT ROOFTOP – 2,000-8,800 CFM
- LE10XINH INDOOR – 2,500-11,000 CFM
- LE10XINV INDOOR – 2,500-11,000 CFM
- LE10XRT ROOFTOP – 2,500-11,000 CFM
- HE07IN INDOOR – 166-694 CFM
- HE07RT ROOFTOP – 166-694 CFM
- HE10IN INDOOR – 250-1,100 CFM
- HE10RT ROOFTOP – 250-1,100 CFM
- HE1.5XINH INDOOR – 375-1,650 CFM
- HE1.5XINV INDOOR – 375-1,650 CFM
- HE1.5XRT ROOFTOP – 375-1,650 CFM
- HE2XINH INDOOR – 500-2,200 CFM
- HE2XINV INDOOR – 500-2,200 CFM
- HE2XRT ROOFTOP – 500-2,200 CFM
- HE2XRTC ROOFTOP – 500-1,700 CFM
- HE3XINH INDOOR – 750-3,300 CFM
- HE3XINV INDOOR – 750-3,300 CFM
- HE3XRT ROOFTOP – 750-3,300 CFM
- HE3XRTC ROOFTOP – 1,100-2,400 CFM
- HE4XINH INDOOR – 1,000-4,395 CFM
- HE4XINV INDOOR – 1,000-4,400 CFM
- HE4XRT ROOFTOP – 1,000-4,345 CFM
- HE4XRTC ROOFTOP – 2,500-3,900 CFM
- HE6XIN INDOOR – 1,500-6,600 CFM
- HE6XRT ROOFTOP – 1,500-6,600 CFM
- HE8XIN INDOOR – 2,000-8,800 CFM
- HE8XRT ROOFTOP – 2,000-8,800 CFM








Helpful Links
At Mits Air, we believe in training.
Features & Benefits
AHRI certified with a near-zero Exhaust Transfer Ratio (EATR) at typical static pressure differential
RenewAire® Core
Offers maximized heat transfer efficiency, easy and low maintenance with no moving parts, and long service life
Cross-flow static-plate technology
No condensation drains required
Humidity control
Up to 70% of sensible and latent energy recovered from exhaust air
Energy Savings
High efficiency filter options (MERV 8 / MERV 13)
High Efficiency
DDC controls option w/ BACnet capability. There are also many control type options such as occupancy sensors, CO2 sensors, IAQ sensors.