Mitsubishi Electric’s Lossnay Energy Recovery Ventilator (ERV) is an optimal solution for enhanced air quality in any application. The Lossnay ERV seamlessly connects to any City Multi VRF system, or in any stand-alone application, and replaces stale indoor air pollutants with fresh, clean and healthy air. It has easy maintenance and uses ultra thin chemically treated paper for superior sensible and latent energy recovery. It recovers energy by reducing the heating or cooling load on the air conditioner or heat pump (by lowering the difference in temperature and humidity between the fresh and indoor air).

For further details, please see the Features and Benefits section below.

Features & Benefits

Heat Exchange Efficiency

Lossnay’s core cross-flow, plate-fin structure of the heat-exchange unit provides unmatched comfort, and specially processed paper fully separates inducted and exhausted air supplies, resulting in the introductions of strictly fresh air to the indoor environment.

Cross-Flow Static-Plate Technology

Lossnay Core is built upon the principle of “Cross-Flow Static-Plate Heat Exchanger”. Fresh air passes through one direction, while stale air passes through a different passage in perpendicular direction separated by partition plates. Both air flows are completely separated, with no gas leakage and no cross contamination. No moving parts are used in the Cross-Flow State-Plate Technology, and thus having the advantages of maximizing heat transfer efficiency, easy and low maintenance, long service life, and no break downs.

Free Cooling with Bypass Ventilation

At times when the outdoor air is cooler than the indoor air, for example in morning or at night or when there is a crowd of people, Lossnay’s built in by-pass damper will activate to bring in the cooler fresh air and reduce the indoor cooling load.

Supremely Quiet

Operating as low as 24dB(a) of sound, Lossnay’s meticulous design results in little air vibration and is widely used as a noise absorption system which can take in an example of 88.2dB of sound and emit a mere 42.9dB.

Ready for Canadian Climates

Lossnay ERV is ready for any Canadian climate with its built-in frost prevention cycle. When the outdoor temperature drops below -10°C, many heat exchange ventilators will be in frequent defrost mode which dramatically reduces the amount of fresh air which can enter the building.Lossnay uses the proactive approach that prevents frost from occurring in these more extreme conditions, where the Supply Air fan in the Lossnay unit will begin intermittent operation, allowing the warm exhaust air to keep water vapour in the core from condensing, and having constant exhaust ventilation rate while maintaining separation in the airstreams.

Contribute to LEED Credits

Lossnay ERV is designed to be an energy saving ventilation system which reduces heating and cooling loads. Lossnay Energy Recovery Ventilator is recognized as a “Green” product and can contribute to the following LEED Credits:

  • EA Prerequisite 2 – Minimum Energy Performance
  • EA Credit 1 – Optimize Energy Performance
  • IEQ Prerequisite 1 – Minimum IAQ
  • IEQ Credit 7 – Thermal Comfort

Head Office: Mississauga

1608 Bonhill Road
Mississauga ON L5T 1C7

1 (800) 567-2221
(905) 564-2221

Hydronics & Unico Division

6125 Netherhart Road
Mississauga, ON L5T 1G5

1 (905) 362-5293

Barrie Branch

691 Dunlop Street W.
Barrie ON L4N 9W9

1 (800) 688-1673
(705) 722-3200

London Branch

90 Towerline Place,
London, ON N6E 2T1

1 (519) 914-9000

Windsor Branch

11629 County Road 42,
Tecumseh, ON N8N 0H1

1 (519) 914-0332

Follow us on

Head Office: Mississauga
1608 Bonhill Road,
Mississauga, ON L5T 1C7
1 (800) 567 - 2221
info@mitsair.com

Hydronics & Unico Division
6125 Netherhart Road,
Mississauga, ON L5T 1G5
1 (905) 362 - 5293
hydronics@mitsair.com

Barrie Branch
691 Dunlop Street W.,
Barrie, ON L4N 9W9
1 (800) 688 -1673
barrie@mitsair.com

London Branch
90 Towerline Place,
London, ON N6E 2T1
1 (519) 914 - 9000
london@mitsair.com

Windsor Branch
11629 County Road 42,
Tecumseh, ON N8N 0H1
1 (519) 914 - 0332
windsor@mitsair.com